Evaluating Ex Vivo Fluorescence Confocal Microscopy for Intraoperative Diagnosis in Pediatric Surgery: A Feasibility Study
dx.doi.org shows its articles on its own site.
Read the article on dx.doi.org ↗Article · Aug 2025 · 1 min read
In brief
In brief
This feasibility study demonstrates that ex vivo fluorescence confocal microscopy can provide rapid, accurate intraoperative tissue diagnosis in pediatric oncology cases without traditional histological processing. Analyzing 18 samples, FCM showed high diagnostic accuracy with perfect interobserver agreement, correctly identifying malignant and benign tissues in real-time during surgery.
- Ex vivo FCM achieved 100% sensitivity and 87.5% specificity for pediatric oncological diagnosis with perfect interobserver agreement (κ=1.00).
- FCM correctly identified all malignant cases (10/10) with no false negatives, critical for intraoperative surgical margin assessment.
- Technology enables real-time tissue diagnosis without standard histological preparation, potentially reducing intraoperative wait times.
- Single false positive (1/18) suggests FCM may overcall benign lesions; confirmatory frozen section may still be needed in select cases.
- Feasibility demonstrated in pediatric population; FCM shows promise as adjunct tool for immediate intraoperative pathology guidance.
Written by the GCMD Library team from the article.
Ex vivo fluorescence confocal microscopy (FCM) is an emerging technology that enables real-time, high-resolution digital imaging of freshly excised tissues without requiring standard histological preparation. This study aims to evaluate the diagnostic performance of FCM compared with conventional histology in a pediatric population with suspected oncological pathology.A total of 18 tissue samples from pediatric patients with suspected oncological lesions were analyzed using FCM. The results were compared with the definitive diagnoses obtained via conventional histology, serving as the gold standard. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess the diagnostic accuracy. Cohen's kappa coefficient (Κ), 95% confidence interval (95% CI), and p-value were computed to evaluate the interobserver agreement and the concordance between FCM and histology.FCM correctly identified 10 positive cases (true positives) and 7 negative cases (true negatives), with 1 false positive and no false negatives. Interobserver agreement was perfect, with a Cohen's kappa coefficient of 1.00 (95% CI: 0.81–1.00, p
Educational content from recorded physician discussions — not medical advice. Talk to your (or your child's) care team about your situation.
Article
The disproportionate burden of severe obesity in youth with special needs and the role of metabolic and bariatric surgery
Published Jun 2026
Video
Pediatric Surgical Oncology Research Collaborative (PSORC): Studying Rare Pediatric Tumors
56 s · Published May 2026
Video
Update Course Rewind 2025: Hirschsprung + ARM: Rare but Real
1 min · Published May 2026
Video
Pooling Patients to Study Rare Pediatric Tumors: An Introduction to PSORC
56 s · Published May 2026
Article
Type of pledget and suture technique relative to esophageal tensile strength in long-gap esophageal atresia
Published May 2026
Video
The fetal frontier: A review of current and emerging fetal therapies for genetic diseases
44 s · Published May 2026