Live Event Content · Button Battery Ingestion
Follow
Video14 min·Published Mar 2020Older

Button Battery Ingestion

Chapter 1 of 5 · Case-Based Learning

Initial management

Case presentation and initial management of button battery ingestion

Try
Intelligent Search· scoped to tracheoesophageal fistula · not medical adviceSearch the whole library →
What the experts said21 expert statements · 2 host summaries
Button battery ingestions are becoming more frequent, with national data suggesting increasing numbers of emergency department visits.
EpidemiologicalDan
A radiographic ring around the edge of a circular object on X-ray indicates a button battery rather than a quarter.
ClinicalDan
The Foley catheter technique may work for button battery removal in limited situations when the operating room cannot be accessed quickly and there is short duration of symptoms without likely perforation.
ClinicalDan
NASPA and the GI group put together criteria and guidelines around management of button batteries with zero input from surgeons.
GuidelineMark
The guidelines mandate multiple MRIs and watching these patients because of concern for vascular injury.
GuidelineMark
The number of ED visits for button battery ingestion has doubled according to data from Colorado.
EpidemiologicalDan
The rate of significant complications from button battery ingestion has increased almost sevenfold.
EpidemiologicalDan
90% of serious outcomes from button battery ingestion occur with 20 millimeter to 25 millimeter batteries.
EpidemiologicalDan
The problematic batteries are lithium batteries that tend to be 3 volt batteries as opposed to 1.5 volt batteries.
ClinicalDan
The pathophysiology of button battery injury is caustic injury from hydroxide ions that rapidly raise the pH in tissue, not erosion of the battery itself or electricity.
ClinicalDan
Complications of button battery ingestion include esophageal perforation, stricture, tracheoesophageal fistula, vocal cord paralysis not associated with perforation, and aortoenteric fistula.
ClinicalDan
Aortoenteric fistula is the most common cause of mortality in button battery ingestion, accounting for 46% of mortalities in the national data bank.
EpidemiologicalDan
Vascular compromise was identified as the etiology in another 29% of mortalities from button battery ingestion.
EpidemiologicalDan
Aortoenteric fistula from button battery ingestion can happen up to 2 weeks post removal of the battery.
ClinicalDan
A trauma one activation system for button battery ingestions reduced time from hitting the door to hitting the OR from 1.5 hours to less than 30 minutes.
Clinical
The recommendation to scope patients when the battery is in the stomach completely flies in the face of actual recommendations from poison.gov, which say you do not need to do that.
GuidelineMark
For relatively minor mucosal injury from button battery, no intervention is needed and symptomatic follow-up is appropriate.
OpinionDan
For circumferential erosions that look bad from button battery injury, re-scoping to look for stricture formation is appropriate.
OpinionDan
If a patient becomes symptomatic after button battery removal, an esophagram should be done to see if they have narrowing or stricture.
ClinicalDan
If performing endoscopy and capable of removing a battery from the stomach endoscopically, removal is advocated because you are already there.
OpinionDan
There is evolving work in animal models using 0.25% acetic acid applied to the area of injury to neutralize caustic damage from button batteries.
Clinical
Authors of a paper presenting 16 cases recommended getting an MRI study after removal of the battery to look at potential impact on surrounding vasculature.
Host summaryDan summarizing the discussion · not cited in answers
Authors advocate that patients should be scoped even if the battery is in the stomach because patients had significant esophageal injuries despite the battery passing to the stomach.
Host summaryDan summarizing the discussion · not cited in answers